P2J Technology is a leading manufacturer of Reeco modular laboratory and workshop table extensions.

Superstructures can be modified in any way and their modular solution offers high variability.

Extensions can be purchased as accessories to existing Reeco tables.

Individual modules are placed in a standardized rack, which can be hung on the upright profiles of Reeco tables, similar to shelves, perforated panels and other accessories.

  • Easy access to securing elements
  • Short-circuit resistance of power supplies
  • Simple exchange of individual modules
  • Possible modifications of the modules according to the customer's wishes
  • Fast implementation

OPTIONAL MODULES

Socket module 230V/16A 4x

Socket module with cover to connect your own devices, power supplies, generators, counters, oscilloscopes, soldering stations and other devices located on the shelf or on the worktop of the Reeco table.

  • Module designation: ZAS230-4
  • Power supply: 1+N+PE ~ 50Hz 230V
  • Switchboard module: ROZV400-xx series, ROZV230-xx series
  • Protection: In the switchboard module, own circuit breaker 16A/B
  • Max. socket current: 16A
  • Degree of protection: IP40

Autotransformer 250V AC/DC

The autotrafe output is switched on by a rocker switch located between the output terminals. When it is turned on, the red on light will light up. At the AC output terminals, there is a voltage corresponding to the position of the knob mark on the scale. For DC output, the voltage will be 1.41 times greater.

  • Module designation: ATR 250V-2A-AC DC
  • Power supply: 1+N+PE ~ 50Hz 230V
  • Switchboard module: ROZV400-xx series, ROZV230-xx series
  • Fuse: Tube fuse 2.5A/T (quick characteristic)
  • Power consumption: 460W max.
  • Output voltage: 0-250VAC, 0-350VDC
  • Output current: 2A max.
  • Degree of protection: IP20

Laboratory power supply 40V/10A/400W

The device is equipped with three segment LED displays indicating:

  • Set / Measured output voltage
  • Set current limitation / Measured output current
  • Mode indication / Measured power supplied to the load
  • Module designation: LABZ40V-10A
  • Power supply: 1+N+PE ~ 50Hz 230V
  • Switchboard module: ROZV400-xx series, ROZV230-xx series
  • Fuse: 10A
  • Source power: 550W max.
  • Output voltage: 0 to 40V, adjustable in 40mV steps
  • Output current: 10A max. continuously
  • Output current limit: 10mA to 10A, adjustable in 10mA steps
  • Output terminals: 4x Terminal for device banana 4mm
  • Degree of protection: IP40

Fixed power supply 24V 2A AC/DC

The output of the source is switched on by a rocker switch located above the output terminals of the source. After turning it on, if everything is in order, the LED located below it will light up green. When the output current exceeds the value of 2A, the electronic reversible fuse is activated, the output of the source is switched off and the LED lights up red.

  • Module designation: Z24V-2A-ACDC
  • Power supply: 1+N+PE ~ 50Hz 230V
  • Switchboard module: ROZV400-xx series, ROZV230-xx series
  • Fuse: 10A
  • Source power: 110W max.
  • Output voltage: ~24V and =24V
  • Output current: 2A for each output
  • Output protection (for each output):
  • Electronic 2A reversible fuse with LED indication
  • 2.5A fusible tube fuse accessible on the panel
  • Output terminals: 2x Terminal for device banana 4mm for each output
  • Degree of protection: IP40

Socket 400V/32A/5P

The voltage in the socket is switched on by turning the switch on the panel to position 1. The presence of voltage in the socket (on the first phase) is indicated by the red "ON" light. The socket is protected by its own 3-pole circuit breaker 16A/B on the module panel.

  • Module designation: ZAS400-1
  • Power supply: 3+N+PE ~ 50Hz 230V/400V
  • Switchboard module: ROZV400-xx series
  • Protection: Circuit breaker 16A/B
  • Socket: CEE 400V/32A/5 poles
  • Max. output current: 16A
  • Level of protection: IP40

Terminal AC output 400V

The voltage on the terminals is switched on by turning the switch on the panel to position 1. The presence of voltage (on the first phase) is indicated by the red "ON" light. The output is protected by its own 3-pole circuit breaker 16A/B on the module panel.

Attention: The output is NOT galvanically separated from the mains!

  • Module designation: Z400V-AC
  • Power supply: 3+N+PE ~ 50Hz 230V/400V
  • Switchboard module: ROZV400-xx series
  • Protection: Circuit breaker 16A/B
  • Output: 4x safety terminal (3L+N), 1x PE terminal
  • Max. output current: 16A
  • Degree of protection: IP20

Panel ammeters 40A/AC/3x

The measured current is fed to a pair of safety terminals next to the selected meter. The zero position of the indicating hand can, if necessary, be reached using a suitable screwdriver directly on the gauge.

Note: The module is only intended for indicative measurement of alternating currents. Not calibrated.

  • Module designation: IM40A-3F-AC40A-3F-AC
  • Measuring range: 5 – 40A
  • Max. meter current: 50A
  • Degree of protection: IP40

Micro soldering iron 90W

Control of the device is described in the supplied instructions for the used QUICK TS1100 micro soldering iron.

  • Module designation: MPAJKA-90W
  • Power supply: 1+N+PE ~ 50Hz 230V
  • Switchboard module: ROZV400-xx series, ROZV230-xx series
  • Protection: circuit breaker 10A/B in the switchboard module
  • Power consumption: 90W
  • Degree of protection: IP40

Modular superstructures

  • We offer racks in two sizes depending on the size of the table:
  • 750mm for tables with a length of 1500mm
  • 900mm for tables with a length of 1200mm or 1800mm
  • The rack occupies half the length of the table and it is possible to place two racks with different modules next to each other or one rack and one shelf to accommodate your own devices
  • Contact us for a price quote tailored to your requirements
IMPORT DATA

COMPREHENSIVE SOLUTIONS

Central control from the teacher's desk

MAKE TOOLPATHS

ADAPTABILITY

At the customer's request, we can fine-tune the color of the table to the company's shades

START MACHINING

SPEED

Only six weeks passed from the first proposal of the solution to the actual implementation

V případě jakýchkoli dotazů nás neváhejte kontaktovat!

Product added to wishlist
Product added to compare.